General specification:
Continuous Output Power :8.0KW
Surge Rating(20s) :24.0KW
Output Waveform :Pure Sine Wave
AC Output Voltage: 220-230-240Vac
AC Input Voltage:220-230-240Vac
DC Battery Voltage:24Vdc
Solar charger Current:60Amp
AC Battery charger:65±5Amp
Output Voltage Regulation :±10% RMS
Output Frequency :50Hz ± 0.3Hz /60Hz ± 0.3Hz
Typical transfer Time :10ms(Max)
DC Input:
Nominal Input Voltage :24.0Vdc
Minimum Start Voltage :20.0Vdc
Low Battery Alarm :21.0Vdc / 22.0Vdc
Low Battery Travel :20.0Vdc / 21.0Vdc
High Voltage Alarm :32.0Vdc
Low Battery voltage get well :31.0Vdc
Idle Consumption-Search Mode :<25 W when Power Saver On
Charger:
Output Voltage: Depends upon battery type
Charger Rating :50A
Max Charge Power Rate: 1/3 Rating Power
Battery Initial Voltage for Start Up: 20-31.4V
Over Charge Protection Shutdown :31.4V
Remote Keep an eye on :Yes
Bypass & Protection:
Input Voltage Waveform :Sine wave (Grid or Generator)
Nominal Voltage:230Vac
Nominal Input Frequency :50Hz or 60Hz
Bypass breaker rating: 50A
Solar Charger controller:
Rated Voltage :24Vdc
Solar Input Voltage Range: 30-70Vdc
Max.PV Open Circuit Array Voltage:105Vdc
Rated Charge Current :60A
Over Charge Disconnection: 29.6V
Over Charge Recovery :27.2V
Over Discharge Disconnection:21.6V
Over Discharge Reconnection :24.6V
Mechanical specification:
Inverter Dimensions(L*W*H) :588*415*200mm
Inverter Weight(Solar Chg)KG: 80
Display :LED +LCD
Standard Warranty :1 Year
* SP-PV Series Pure Sine Wave Inverter is a combination of an inverter, AC charger, Mppt solar charger and Auto-transfer switch into one complete system . It’s packed with unique features and it is among the such a lot advanced inverter/chargers available in the market as of late.
* Frequency adjust: The frequency of the inverter is arranged by the SW4. The default configuration for 220/230/240VAC inverter is 50Hz, and 60Hz for 100/110/120VAC inverter. Even as the output freq will also be easily changed once a qualified freq is applied to the inverter Protections:AC Input over voltage protection/AC Input low voltage protection,Low battery alarm/High battery alarm,Over temperature protection/Over load protection,Short Circuit protection (1sec after fault),Back feeding protection.
* Applicantion:for the entire forms of load: circular saws, drills, grinders, sanders, buffers, weed and hedge trimmers, air compressors.computers, printers, monitors, facsimile machines, scanners. vacuum cleaners, fans, fluorescent and incandescent lights, shavers, sewing machines.coffee makers, blenders, ice markers, toasters.metal halide lamp, high – pressure sodium lamp.tv, VCRs, video games, stereos, musical instruments, satellite equipment ect.
* Our inverter is designed with AC priority by default. This implies, when AC input is present, the battery might be charged first, and the inverter will transfer the input AC to power the weight.The AC Priority and Battery Priority switch is SW4. When you select battery priority, the inverter will inverting from battery regardless of the AC input. Only when the battery voltage is reaches low voltage alarm,the inverter transfers to AC Input, charges battery, and switches back to battery when battery is charged full. This function is basically for wind/solar systems taking utility power as back up.
* SP-PV Series Inverter is equipped with a powerful charger of as much as 120Amp (depending on Model). The overload capacity is three hundred% of continuous output for as much as 20 seconds to reliably reinforce tools and equipment longer. the max chargecurrent will also be adjusted from 0%-100% by the use of a liner switch on the right of the battery type selector. This might be helpful if you’re the usage of our powerful charger on a small capacity battery bank. Fortunately, the lining switch can effectively reduce the max charging current to twenty% of its peak. Choosing “0” within the battery type selector will disable charging function.